An SCR system throwing derate codes or burning more diesel exhaust fluid than usual often points to a failed Cummins Nitrogen Oxide (NOx) Sensor rather than a fluid problem. Two sensors typically monitor the system, one before and one after the SCR catalyst, comparing readings to confirm the catalyst is actually reducing emissions as designed. A sensor reporting inaccurate readings can trigger unnecessary derates or let a genuine emissions problem go undetected behind a false-passing reading. The Cummins 5491423RX uses the same heater circuit and signal output the control module expects, restoring accurate readings at either monitoring position.